Ge Mac 500 Ecg Machine Service Manual

Posted on by
Ge Mac 500 Ecg Machine Service Manual 4,6/5 4837 votes

The MAC 5500 HD system brings you improved functionality and clinical workflow while maintaining the familiar look and ease of use you expect from a GE Healthcare ECG system. And our training programs ensure that you get the most from your ECG equipment investment while supporting the ongoing education of your clinicians. Sets of cables, 2 bxs EKG paper, 1pk of electrodes and user manual 10 lead ecg ekg cable for ge marquette mac 500, 1200,1100,mac 1200st zero - with a new ad-powered trading service it is. The GE MAC 5500 EKG Machine with Interpretation has the ability to perform a 15 lead analysis with interpretation (12 SL EKG analysis program with Gender Specific Software). The information is displayed on a 10.4” backlit color AM-LCD display. It includes a full alphanumeric keyboard, making it easier to input patient demographics. View and Download GE MAC 5000 operator's manual online. Resting ecg analysis system. MAC 5000 Medical Equipment pdf manual download. See the MAC 5000 Service Manual for more battery maintenance and diagnostic information. After removing and replacing the battery, the battery gauge symbol resets to empty.

  1. Ge Mac 5000 Service Manual
  2. Ge Ekg Machine Mac 1200
  3. Mac 5000 Ekg Machine Manual
Introduction .. . .. 1-1 Manual Information .. . .. 1-3 Revision History .. . .. 1-3 Manual Purpose .. . .. 1-3 Intended Audience .. . .. 1-3 Warnings, Cautions, and Notes .. . .. 1-4 Safety Messages .. . .. 1-5 Responsibility of the Manufacturer .. . .. 1-5 General .. . .. . . 1-5 Equipment Symbols .. . .. 1-7 Service Information .. . .. 1-8 Service Requirements .. . .. 1-8 Equipment Identification .. . .. 1-8 Format A .. . .. 1-9 Format B .. . .. 1-10 Equipment Overview .. . .. 2-1 General Description .. . .. 2-3 Front View .. . .. 2-3 Back View .. . .. 2-3 Connector Identification .. . .. 2-4 Detailed Description .. . .. 2-5 Block Diagram .. . .. 2-8 Theory of Operation .. . .. 2-11 Power Supplies .. . .. 2-11 Clocks .. . .. 2-13 CPU .. . .. 2-13 FPGA Internal Logic .. . .. 2-13 SDRAM .. . .. 2-20 SmartMedia Card .. . .. 2-20 Serial EEPROM .. . .. 2-20 VGA LCD/CRT Interface .. . .. 2-21 Acquisition Module Transceiver / Power Switch .. . .. 2-2 COMM Port Power Switch / Current Limiter .. . .. 2-22 Thermal Printhead Power / Pixel Test Hardware .. . .. 2-23 Super I/O Peripheral Controller .. . .. 2-23 The Four Stooges .. . .. 2-24 Untested “Nominal” Operating Time Specs .. . .. 2-30 Installation .. . .. 3-1 Preparation for Use .. . .. 3-3 General .. . .. . . 3-3 Trolley Height Adjustment .. . .. 3-4 Installing the MAC 5000 .. . .. 3-6 Installing the Modem Kit .. . .. 3-8 Magnetic Card Reader Installation .. . .. 3-10 Bar Code Reader Installation .. . .. 3-12 Type-S Trolley Assembly .. . .. 3-14 MAC 5000 ST Requirements and Configuration .. . .. 3-15 Compatible Blood Pressure Units .. . .. 3-16 Analog Treadmills .. . .. 3-16 Bicycle Ergometers .. . .. 3-17 Maintenance .. . .. 4-1 Introduction .. . .. . . . 4-3 Recommended Maintenance .. . .. 4-3 Required Tools and Supplies .. . .. 4-3 Inspection and Cleaning .. . .. 4-4 Visual Inspection .. . .. 4-4 Exterior Cleaning .. . .. 4-4 Interior Cleaning .. . .. 4-4 General .. . .. 4-4 Thermal Printhead .. . .. 4-5 Battery and Patient Cable Replacement .. . .. 4-6 Battery Replacement .. . .. 4-6 Patient Cable Replacement .. . .. 4-6 Disassembly Guidelines .. . .. 4-7 Preliminary Steps .. . .. 4-7 Trolley Disassembly .. . .. 4-7 Type-S Trolley Disassembly .. . .. 4-8 Power Supply .. . .. 4-8 Top Cover .. . .. 4-9 Display/Keyboard Assembly .. . .. 4-1 Removal .. . .. 4-11 Display/Keyboard Reassembly .. . .. 4-12 Reassembly .. . .. 4-13 Main PCB .. . .. 4-13 Removal .. . .. 4-13 Reassembly .. . .. 4-14 Printhead Replacement .. . .. 4-14 Removal .. . .. 4-14 Reassembly .. . .. 4-14 Diskette Drive Removal/Replacement .. . .. 4-15 Writer Roller/Carriage Assembly .. . .. 4-15 Removal .. . .. 4-15 Reassembly .. . .. 4-16 Trolley Casters .. . .. 4-17 Domestic Electrical Safety Tests .. . .. 4-19 AC Line Voltage Test .. . .. 4-19 Leakage Tests .. . .. 4-20 Troubleshooting .. . .. 5-1 Assembly Descriptions .. . .. 5-3 Introduction .. . .. 5-3 Assembly Block Diagram .. . .. 5-3 General Fault Isolation .. . .. 5-4 Power-up Self-test .. . .. 5-4 Power-up Flow Chart .. . .. 5-5 Poor Quality ECGs .. . .. 5-5 Visual Inspection .. . .. 5-6 Diagnostic Tests .. . .. 5-7 Introduction .. . .. 5-7 Loading the System Diagnostics .. . .. 5-7 Substitute Master Password .. . .. 5-7 System Diagnostics Main Menu .. . .. 5-8 Display Tests .. . .. 5-8 Pixel Verification Test .. . .. 5-8 Grey Scale Test Patterns .. . .. 5-8 Speaker Test .. . .. 5-9 Keyboard Test .. . .. 5-9 PS2 Port Test .. . .. 5-9 Writer Tests .. . .. 5-10 Battery Tests .. . .. 5-12 Battery Status .. . .. 5-12 Battery Discharge Test .. . .. 5-12 Battery Charge Test .. . .. 5-12 Print Charge/Discharge Test Results .. . .. 5-1 Communication Tests .. . .. 5-13 COM Port Loopback Test .. . .. 5-13 Modem Test .. . .. 5-13 Acquisition Module Test .. . .. 5-13 Analog I/O Tests .. . .. 5-13 Analog Output Test .. . .. 5-13 Analog Input Test .. . .. 5-14 DCOut Loopback Test .. . .. 5-14 ECGOut/QRSTrigger Loopback Test .. . .. 5-14 Floppy Drive Tests .. . .. 5-14 Diskette Format Failure .. . .. 5-14 Equipment Problems .. . .. 5-15 ECG Data Noise .. . .. 5-15 Missing ACI-TIPI Report .. . .. 5-15 No BP from External Device .. . .. 5-15 Treadmill/Ergometer Does Not Move .. . .. 5-15 System Errors .. . .. 5-16 Frequently Asked Questions .. . .. 5-17 Maintenance .. . .. 5-17 Save Setups .. . .. 5-17 Storing ECGs .. . .. 5-17 Format a Disk .. . .. 5-17 Cleaning .. . .. 5-17 Battery Capacity .. . .. 5-18 System Setup .. . .. 5-18 Location Number .. . .. 5-18 Patient Questions .. . .. 5-18 Passwords .. . .. 5-19 Clinical .. . .. . . 5-19 Report Format .. . .. 5-19 Hi-Res and Phi-Res .. . .. 5-19 Editing .. . .. 5-19 Entering Patient Data .. . .. 5-20 Transmission .. . .. 5-20 Losing Fields When Transmitting .. . .. 5-20 Input and Output Connectors .. . .. 5-21 A Pins (J1) .. . .. 5-21 COM1 (COM3/4) Pins (J3) .. . .. 5-21 COM2 Pins (J5) .. . .. 5-22 Analog Pins (J6) .. . .. 5-22 EXT. VID. Pins (J7) .. . .. 5-23 CPU PCB Input/Output Signals .. . .. 5-24 Battery Pack/Monitor, J2 .. . .. 5-24 LCD Backlight, J4 .. . .. 5-24 Keyboard, J8 .. . .. 5-24 LCD, J10 .. . .. 5-2 Power Supply/Motor, J11 .. . .. 5-26 Thermal Printer, J12 .. . .. 5-27 Floppy Disk Drive, J13 .. . .. 5-28 Acquisition Module, J14 .. . .. 5-29 Parts List .. . .. 6-1 Ordering Parts .. . .. . . 6-3 General Information .. . .. 6-3 Field Replaceable Units .. . .. 6-4 Appendices Appendix A – Abbreviations .. . .. .A-1 Standard Abbreviations .. . .. A-3 Appendix B – Technical Specifications .. . . . .B-1 Technical Specifications .. . .. B-3 Display .. . .. . . .B-3 Computerized Electrocardiograph .. . .. .B-3 Writer .. . .. . . .B-4 Keyboard .. . .. .B-4 Electrical .. . .. .B-4 Vectorcardiography .. . .. .B-4 Hi-Res and PHi-Res Signal-Averaged Electrocardiography . . . .. .B-5 Physical .. . .. .B-5 Environmental .. . .. .B-5 Safety .. . .. . . .B-7 Appendix C – Electromagnetic Compatibility .. .C-1 Electromagnetic Compatibility (EMC) .. . .. C-3 Guidance and Manufacturer’s Declaration – Electromagnetic Emissions .. .C-3 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity .. .C-4 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity .. .C-5 Recommended Separation Distances .. . .. .C-6 Compliant Cables and Accessories .. . .. .C-7

Description

Ge Mac 5000 Service Manual

The GE MAC 5500 EKG Machine with Interpretation has the ability to perform a 15 lead analysis with interpretation (12 SL EKG analysis program with Gender Specific Software). The information is displayed on a 10.4” backlit color AM-LCD display. It includes a full alphanumeric keyboard, making it easier to input patient demographics. With its single button operation for printing, storage, and transmitting, makes it truly easy to use and will help streamline your workflow. The GE MAC 5500 EKG has the ability to provide full page printouts. With a single button for operating it can print, store and transmit data almost instantly. An optional barcode scanner can be used to help reduce clerical errors and help input patient data.

The MAC® 5500 system advances clinical workflow with a variety of networked solutions. Linked communication allows you to store and retrieve your data more efficiently – and opens the door for more informed clinical decision making. What’s more, access to patient information maximizes departmental productivity while reducing the chance of errors. The result is a premier resting ECG system that helps you make faster, more confident cardiac assessments and provide better patient care.

Built on GE innovation, the MAC 5500 EKG System is a premier EKG system, delivering advanced disease management capabilities through one of the industry-leading collections of algorithms and advanced networking. The MAC 5500 represents a new definition of EKG speed and accuracy, and offers:

You can also switch among the three main calculation options using the Calculation Options button in the Calculation section of the Formulas tab on the Ribbon. Excel manual calculation shortcut. If you would rather not turn off automatic calculation, you can try using this feature (if you have multiple processors in your computer) to reduce calculation time.To enable the multi-threading feature, click the FILE tab and select Options to open the Excel Options dialog box, as mentioned earlier. However, if you want to set the iteration options, you must use the Formulas page on the Word Options dialog box.Excel 2013 has a multi-threading feature that allows you to reduce the time it takes to calculate complex formulas. Click Advanced in the menu on the left.Scroll down to the Formulas section and select the Enable multi-threaded calculation check box so there is a check mark in the box.

  • Better triaging tools for Acute Coronary Syndrome (ACS) detection
  • Configurable Crtical Values to help speed time to treatment
  • More accurate pacemaker detection for advanced interpretation of paced rhythms
  • Enhanced barcode workflow, with orders and ADT download capability, work together to help improve efficiency across the enterprise
  • Connected ECG Workflow to help save time and avoid costly misdiagnoses

The MAC 5500 EKG also meets the need for productivity across the enterprise, by empowering a wide range of users to precisely capture, analyze, and communicate EKG data. All to ensure the right data goes with the right patient to help reduce demographic and billing errors, and speed time to treatment. Sophisticated tools. Ease of use. The MAC 5500 EKG enables clinicians to focus on what’s most important – their patients.

Ops ManualTech ManualBrochureGe ekg machine 5500 manual

Ge Ekg Machine Mac 1200

5000

Mac 5000 Ekg Machine Manual

Brochure 2